Management of acute right heart failure

Informações:

Sinopse

The two major causes of acute right ventricular (RV) failure in ICU patients are acute cor pulmonale (ACP) during acute respiratory distress syndrome (ARDS) and ACP during acute massive pulmonary embolism (PE).   The increase in pulmonary vascular resistance (PVR) in ARDS can be secondary either to « structural » mechanisms related to lung injury per se and to « functional » mechanisms related to the effects of mechanical ventilation with positive end expiratory pressure (PEEP). The latter mechanism is enhanced when PEEP overdistends more than it recruits lung volume and when tidal volume (VT) is high. The recommended protective ventilation with low VT and PEEP adjusted to driving pressure can also reduce the RV afterload. A reduced central blood volume can also play a role in the increase in PVR (extension of the West’s zone 2). In this case, volume administration can reduce the PVR and improve the RV function. Finally, prone positioning also exerts a beneficial effect on RV afterload through a decrease in